YDCHARGE Wall-Mounted DC EV Charger is a compact DC charging solution designed for home-adjacent parking, workplace charging, commercial parking, fleet depots, workshops and small public charging sites. Available in 7 kW, 15 kW, 20 kW, 30 kW and 40 kW power ratings, it delivers stable DC charging performance in a slim enclosure that can be configured for wall-mounted or pedestal-mounted installation.
7 kW, 15 kW, 20 kW, 30 kW, 40 kW
CCS1, CCS2, CHAdeMO, GB/T, NACS
OCPP 1.6J, RFID, App Control
IP54 | Wall & Pedestal Mount
The charger supports CCS1, CCS2, CHAdeMO, GB/T and NACS project options according to target market, vehicle platform and validation requirements. With OCPP 1.6J, RFID card authorization, remote operation, app access through Wi-Fi and Bluetooth, a 4.3 inch color touchscreen display, IP54 protection and OEM/ODM customization, it provides a practical compact DC charging platform for private, commercial, fleet and network charging projects.
YDCHARGE Wall-Mounted DC EV Charger
YDCHARGE Wall-Mounted DC EV Charger is developed for sites that require compact DC charging without the footprint and infrastructure complexity of large high-power DC charging stations. It is suitable for home-adjacent parking, office parking, shopping centers, apartment parking areas, hotels, fleet depots, workshops and small commercial charging stations.
Product Overview and Strategic Sizing
Power Range Flexibility
The charger is available in 7 kW, 15 kW, 20 kW, 30 kW and 40 kW versions. The 7 kW version is best positioned as a compact low-power DC charger for limited-space applications. The 15 kW to 40 kW versions are suitable for faster DC charging in commercial, fleet, workplace and destination charging scenarios. This power range gives project owners flexibility to match charging performance with available grid capacity, installation budget and site layout.
The DC Charging Advantage
Compared with AC charging, DC charging supplies power directly to the vehicle battery through the DC charging interface. This allows operators to provide a more controlled charging experience where compatible vehicles and DC charging interfaces are used.
Deployment Flexibility and Interface Options
Mounting Configurations:
The charger supports both wall-mounted and pedestal-mounted installation. Wall-mounted installation is suitable for garages, workshops, private parking areas and space-limited commercial locations. Pedestal-mounted installation is suitable for parking lots, fleet depots, public access charging points and commercial sites where a freestanding structure is required.
Global Interface Suitability:
Connector options can include CCS1, CCS2, CHAdeMO, GB/T and NACS according to project requirements. Final connector configuration should be confirmed according to vehicle compatibility, local charging standards, communication protocol, certification scope and regional deployment requirements. NACS should be treated as a project option subject to compatibility validation and market requirements.
Smart Operation and Network Integration
For smart operation, the charger supports OCPP 1.6J for connection with compatible charging management platforms. Operators can manage charging sessions, user authorization, charging records, fault reporting, remote start and stop, reservation functions, offline billing logic and maintenance support through a backend system. RFID card access, password authorization, VIN-based authorization, local automatic charging and app access through Wi-Fi and Bluetooth can be configured according to the application scenario.
Plug & Charge Framework Note:
ISO 15118 based Plug & Charge should be treated as a separate project configuration. It depends on vehicle compatibility, certificate handling, backend support and the selected protocol stack, and should not be assumed to be included in every version.
Thermal Engineering and System Protections
Separated Air Duct Structure
The charger uses a separated air inlet and outlet structure to improve thermal performance during DC charging. This airflow design helps move heat away from key components, supports stable output performance and improves long-term reliability in indoor and semi-outdoor commercial environments.
System Protection Matrix
The system can support key electrical and operational protection functions, including emergency stop, over-voltage protection, under-voltage protection, over-current protection, over-temperature protection, short-circuit protection, leakage protection, lightning protection, insulation monitoring and reverse battery protection, depending on selected configuration and certification scope. Final protection functions should be confirmed according to the selected datasheet and project configuration.
Enclosure and Climate Suitability
The IP54-rated enclosure supports use in suitable indoor, covered outdoor and semi-outdoor environments. For outdoor deployment, installation should consider shelter, ventilation, drainage, direct sunlight, rain exposure, cable routing and local electrical requirements. IP54 should not be presented as fully waterproof or suitable for unsheltered long-term exposure in severe weather. The charger operates from -20°C to +50°C and supports power derating at high temperatures. Heater options can be configured for cold regions according to project requirements, helping improve stability across different climates. Storage temperature range is from -40°C to +85°C under non-condensing conditions.
OEM/ODM Customization and Compliance
Project Customization Scope
YDCHARGE supports OEM and ODM customization for global DC charging projects. Available customization options include:
Connector type
Charging cable length
Enclosure color
Logo integration
HMI interface
Language selection
RFID function
Communication module
Backend integration
Market-specific compliance
Standards and Protocol Architecture
Standard and protocol support may include IEC 61851-23, IEC 61851-24, IEC 62196, GB/T 18487, GB/T 20234, GB/T 27930, CHAdeMO, DIN 70121, ISO 15118 and OCPP 1.6J, depending on selected configuration.
Final protocol support, certification scope and vehicle compatibility should be confirmed according to the selected power rating, connector type, software stack, regional market and project validation requirements.
YDCHARGE Wall-Mounted DC EV Charger Technical Specifications
| Item | 7 kW | 15 kW | 20 kW | 30 kW | 40 kW |
|---|---|---|---|---|---|
| Electrical Input and Output Specifications | |||||
| Product Type | Compact DC EV Charger | Compact DC EV Charger | Compact DC EV Charger | Compact DC EV Charger | Compact DC EV Charger |
| Output Power | 7 kW | 15 kW | 20 kW | 30 kW | 40 kW |
| Input Voltage | 90 to 265 V AC, 220 V rated | 260 to 475 V AC, 380 V rated | |||
| Working Frequency | 47 to 63 Hz | ||||
| Power Factor | ≥0.99 | ||||
| Input Current | 32 A | 30 A | 32 A | 60 A | 67 A |
| Output Voltage | 200 to 750 V DC | 200 to 750 V DC | 200 to 750 V DC / 200 to 1000 V DC | ||
| Output Current | 0 to 20 A | 0 to 37.5 A | 0 to 50 A | 0 to 100 A | 0 to 134 A |
| Auxiliary Source | GB/T: 12 V, 24 V optional; CCS / CHAdeMO: 12 V | ||||
| Mechanical, Environmental and Enclosure Parameters | |||||
| Installation | Wall-mounted / Pedestal-mounted | ||||
| Machine Size | 548 × 378 × 160 mm | 642 × 454 × 153 mm | 667 × 475 × 204 mm | ||
| Packing Size | Carton: 790 × 610 × 380 mm; wooden box: 790 × 610 × 470 mm | Carton: 940 × 605 × 465 mm; wooden box: 945 × 610 × 500 mm | |||
| Packing Weight | Carton: 32 kg; wooden box: 41 kg |
Carton: 41 kg; wooden box: 59 kg |
Carton: 45 kg; wooden box: 64 kg |
Carton: 61 kg; wooden box: 69 kg |
Carton: 70 kg; wooden box: 80 kg |
| IP Rating | IP54 | ||||
| Operating Temp | -20°C to +50°C | ||||
| Operating Humidity | 5% to 90% RH, non-condensing | ||||
| Operating Altitude | ≤2000 m | ||||
| Storage Temp | -40°C to +85°C | ||||
| Storage Humidity | 5% to 95% RH, non-condensing | ||||
| Interface, Protocols and Smart Connectivity | |||||
| User Interface | 4.3 inch color touchscreen display | ||||
| Cable Length | 5 m, including connector head and approx. 4.5 m actual cable | ||||
| Charging Modes | Local automatic charging / OCPP / RFID card / password / reservation / offline billing / app via Wi-Fi and Bluetooth | ||||
| Connector Options | GB/T, CCS1, CCS2, CHAdeMO, NACS optional | ||||
| Standard Support | GB/T 18487, GB/T 20234, GB/T 27930; EN 61851, EN 62196, ISO 15118, DIN 70121; CHAdeMO, depending on configuration | ||||
Wall-Mounted DC EV Charger FAQs