YDCHARGE Compact DC Charging Station | 7 kW to 40 kW OEM/ODM DC EV Charger Platform | CCS1, CCS2, CHAdeMO, GB/T and NACS Options

YDCHARGE Wall-Mounted DC EV Charger is a compact DC charging solution designed for home-adjacent parking, workplace charging, commercial parking, fleet depots, workshops and small public charging sites. Available in 7 kW, 15 kW, 20 kW, 30 kW and 40 kW power ratings, it delivers stable DC charging performance in a slim enclosure that can be configured for wall-mounted or pedestal-mounted installation.

Power Ratings
7 kW, 15 kW, 20 kW, 30 kW, 40 kW
DC Connectors
CCS1, CCS2, CHAdeMO, GB/T, NACS
Smart Operation
OCPP 1.6J, RFID, App Control
Enclosure Protection
IP54 | Wall & Pedestal Mount

The charger supports CCS1, CCS2, CHAdeMO, GB/T and NACS project options according to target market, vehicle platform and validation requirements. With OCPP 1.6J, RFID card authorization, remote operation, app access through Wi-Fi and Bluetooth, a 4.3 inch color touchscreen display, IP54 protection and OEM/ODM customization, it provides a practical compact DC charging platform for private, commercial, fleet and network charging projects.

YDCHARGE Wall-Mounted DC EV Charger

YDCHARGE Wall-Mounted DC EV Charger is developed for sites that require compact DC charging without the footprint and infrastructure complexity of large high-power DC charging stations. It is suitable for home-adjacent parking, office parking, shopping centers, apartment parking areas, hotels, fleet depots, workshops and small commercial charging stations.

Product Overview and Strategic Sizing

Power Range Flexibility

The charger is available in 7 kW, 15 kW, 20 kW, 30 kW and 40 kW versions. The 7 kW version is best positioned as a compact low-power DC charger for limited-space applications. The 15 kW to 40 kW versions are suitable for faster DC charging in commercial, fleet, workplace and destination charging scenarios. This power range gives project owners flexibility to match charging performance with available grid capacity, installation budget and site layout.

The DC Charging Advantage

Compared with AC charging, DC charging supplies power directly to the vehicle battery through the DC charging interface. This allows operators to provide a more controlled charging experience where compatible vehicles and DC charging interfaces are used.

Deployment Flexibility and Interface Options

Mounting Configurations:

The charger supports both wall-mounted and pedestal-mounted installation. Wall-mounted installation is suitable for garages, workshops, private parking areas and space-limited commercial locations. Pedestal-mounted installation is suitable for parking lots, fleet depots, public access charging points and commercial sites where a freestanding structure is required.

Global Interface Suitability:

Connector options can include CCS1, CCS2, CHAdeMO, GB/T and NACS according to project requirements. Final connector configuration should be confirmed according to vehicle compatibility, local charging standards, communication protocol, certification scope and regional deployment requirements. NACS should be treated as a project option subject to compatibility validation and market requirements.

Smart Operation and Network Integration

For smart operation, the charger supports OCPP 1.6J for connection with compatible charging management platforms. Operators can manage charging sessions, user authorization, charging records, fault reporting, remote start and stop, reservation functions, offline billing logic and maintenance support through a backend system. RFID card access, password authorization, VIN-based authorization, local automatic charging and app access through Wi-Fi and Bluetooth can be configured according to the application scenario.

Plug & Charge Framework Note:

ISO 15118 based Plug & Charge should be treated as a separate project configuration. It depends on vehicle compatibility, certificate handling, backend support and the selected protocol stack, and should not be assumed to be included in every version.

Thermal Engineering and System Protections

Separated Air Duct Structure

The charger uses a separated air inlet and outlet structure to improve thermal performance during DC charging. This airflow design helps move heat away from key components, supports stable output performance and improves long-term reliability in indoor and semi-outdoor commercial environments.

System Protection Matrix

The system can support key electrical and operational protection functions, including emergency stop, over-voltage protection, under-voltage protection, over-current protection, over-temperature protection, short-circuit protection, leakage protection, lightning protection, insulation monitoring and reverse battery protection, depending on selected configuration and certification scope. Final protection functions should be confirmed according to the selected datasheet and project configuration.

Enclosure and Climate Suitability

The IP54-rated enclosure supports use in suitable indoor, covered outdoor and semi-outdoor environments. For outdoor deployment, installation should consider shelter, ventilation, drainage, direct sunlight, rain exposure, cable routing and local electrical requirements. IP54 should not be presented as fully waterproof or suitable for unsheltered long-term exposure in severe weather. The charger operates from -20°C to +50°C and supports power derating at high temperatures. Heater options can be configured for cold regions according to project requirements, helping improve stability across different climates. Storage temperature range is from -40°C to +85°C under non-condensing conditions.

OEM/ODM Customization and Compliance

Project Customization Scope

YDCHARGE supports OEM and ODM customization for global DC charging projects. Available customization options include:

Power rating
Connector type
Charging cable length
Enclosure color
Logo integration
HMI interface
Language selection
RFID function
Communication module
Backend integration
Market-specific compliance

Standards and Protocol Architecture

Standard and protocol support may include IEC 61851-23, IEC 61851-24, IEC 62196, GB/T 18487, GB/T 20234, GB/T 27930, CHAdeMO, DIN 70121, ISO 15118 and OCPP 1.6J, depending on selected configuration.

Final protocol support, certification scope and vehicle compatibility should be confirmed according to the selected power rating, connector type, software stack, regional market and project validation requirements.

Specify your required installation orientation, target market connection standards, and software backend constraints to coordinate with our technical deployment teams.

YDCHARGE Wall-Mounted DC EV Charger Technical Specifications

Item 7 kW 15 kW 20 kW 30 kW 40 kW
Electrical Input and Output Specifications
Product Type Compact DC EV Charger Compact DC EV Charger Compact DC EV Charger Compact DC EV Charger Compact DC EV Charger
Output Power 7 kW 15 kW 20 kW 30 kW 40 kW
Input Voltage 90 to 265 V AC, 220 V rated 260 to 475 V AC, 380 V rated
Working Frequency 47 to 63 Hz
Power Factor ≥0.99
Input Current 32 A 30 A 32 A 60 A 67 A
Output Voltage 200 to 750 V DC 200 to 750 V DC 200 to 750 V DC / 200 to 1000 V DC
Output Current 0 to 20 A 0 to 37.5 A 0 to 50 A 0 to 100 A 0 to 134 A
Auxiliary Source GB/T: 12 V, 24 V optional; CCS / CHAdeMO: 12 V
Mechanical, Environmental and Enclosure Parameters
Installation Wall-mounted / Pedestal-mounted
Machine Size 548 × 378 × 160 mm 642 × 454 × 153 mm 667 × 475 × 204 mm
Packing Size Carton: 790 × 610 × 380 mm; wooden box: 790 × 610 × 470 mm Carton: 940 × 605 × 465 mm; wooden box: 945 × 610 × 500 mm
Packing Weight Carton: 32 kg;
wooden box: 41 kg
Carton: 41 kg;
wooden box: 59 kg
Carton: 45 kg;
wooden box: 64 kg
Carton: 61 kg;
wooden box: 69 kg
Carton: 70 kg;
wooden box: 80 kg
IP Rating IP54
Operating Temp -20°C to +50°C
Operating Humidity 5% to 90% RH, non-condensing
Operating Altitude ≤2000 m
Storage Temp -40°C to +85°C
Storage Humidity 5% to 95% RH, non-condensing
Interface, Protocols and Smart Connectivity
User Interface 4.3 inch color touchscreen display
Cable Length 5 m, including connector head and approx. 4.5 m actual cable
Charging Modes Local automatic charging / OCPP / RFID card / password / reservation / offline billing / app via Wi-Fi and Bluetooth
Connector Options GB/T, CCS1, CCS2, CHAdeMO, NACS optional
Standard Support GB/T 18487, GB/T 20234, GB/T 27930; EN 61851, EN 62196, ISO 15118, DIN 70121; CHAdeMO, depending on configuration
The packing weight is a reference value for standard configuration only. If accessories, connector options or project-specific components are added, the actual weight shall prevail. Specifications may vary by power rating, connector type, protocol stack, regional certification, software configuration and project requirements. Please confirm the final datasheet before ordering.

Wall-Mounted DC EV Charger FAQs

B2B OEM/ODM Frequently Asked Questions

Q1. What is this wall-mounted DC EV charger designed for?
It is designed for compact DC charging applications, including home-adjacent parking, workplace charging, commercial parking, fleet depots, workshops and small public charging sites.
Q2. What power ratings are available?
The charger is available in 7 kW, 15 kW, 20 kW, 30 kW and 40 kW versions. The 7 kW version is best positioned as compact low-power DC charging, while the 15 kW to 40 kW versions are suitable for faster DC charging in commercial, workplace and fleet applications.
Q3. Is the 7 kW version a DC fast charger?
The 7 kW version is a low-power DC charger. It provides DC output through the vehicle’s DC charging interface, but it should be positioned as compact DC charging rather than ultra-fast charging.
Q4. Does it support both wall-mounted and pedestal-mounted installation?
Yes. The charger can be supplied in wall-mounted or pedestal-mounted configurations according to site layout, installation space and project requirements.
Q5. Which charging connectors are supported?
The charger can be configured with CCS1, CCS2, CHAdeMO, GB/T and NACS connectors according to target market and project requirements. Final compatibility depends on connector hardware, communication protocol, vehicle platform and validation scope.
Q6. Does it support NACS?
NACS can be provided as a project option. Final support should be confirmed according to connector specification, DC charging requirements, vehicle compatibility, protocol implementation and regional deployment requirements.
Q7. Does the charger support OCPP?
Yes. The charger supports OCPP 1.6J for connection with compatible charging management platforms. Backend integration should be validated according to the selected platform and project configuration.
Q8. Can the charger be connected to a charging management platform?
Yes. With OCPP 1.6J support, the charger can connect to compatible management platforms for remote monitoring, authorization, charging records, fault reporting, remote start and stop, reservation functions and operation management.
Q9. Does it support automatic charging or Plug & Charge?
Local automatic charging can be configured for selected applications. ISO 15118 based Plug & Charge requires project-specific configuration, vehicle compatibility, certificate handling and backend support.
Q10. What user authorization methods are available?
Depending on project configuration, the charger can support RFID card authorization, password access, VIN-based authorization, backend platform authorization, local automatic charging, reservation functions, offline billing logic and app access through Wi-Fi and Bluetooth.
Q11. Is this charger suitable for outdoor installation?
The charger is rated IP54 and can be used in suitable indoor, covered outdoor and semi-outdoor environments. It should not be described as fully waterproof. Outdoor installation should consider shelter, ventilation, drainage, direct sunlight, rain exposure and local electrical requirements.
Q12. What safety protections are available?
Depending on configuration, the charger can support emergency stop, over-voltage protection, under-voltage protection, over-current protection, over-temperature protection, short-circuit protection, leakage protection, lightning protection, insulation monitoring and reverse battery protection.
Q13. Can the charger be customized for OEM/ODM projects?
Yes. YDCHARGE supports customization of power rating, connector type, cable length, enclosure design, logo, HMI language, communication module, RFID function, backend integration and market-specific compliance configuration.
Q14. What standards and protocols can be supported?
Depending on configuration, the charger can support IEC 61851-23, IEC 61851-24, IEC 62196, GB/T 18487, GB/T 20234, GB/T 27930, CHAdeMO, DIN 70121, ISO 15118 and OCPP 1.6J related requirements. Final support should be confirmed according to selected configuration and project validation scope.
Q15. What should be confirmed before ordering?
Before ordering, customers should confirm power rating, input supply, connector type, protocol requirements, cable length, target market, installation method, certification scope, backend integration, charging mode and vehicle compatibility.

Specify your required installation orientation, target market connection standards, and software backend constraints to coordinate with our technical deployment teams.